Search:
Producers: 76 Designers: 66 720 Number of CAD drawings: 166 009
Archispace « Manufacturers « HALFEN Contact « Details catalog « Fire Protection systems « The fire series VF50 RR EI60

The fire series VF50 RR EI60

Drawings

Profile fire VF50 RR EI60 - section

Descriptions

Facade design, mullion-transom, thermally insulated (RMG 1.0). Variant bolt / bolt, which profiles a kind used for the pions (columns) and levels (bolts). Solution EI60.

Dimension of the profile view 50 mm.
Mullion-transom construction, insulated, designed for vertical facades.
This is a design based on the profiles of one type, used both divisions (columns) which levels (bolts) - the same geometry but different profile depths.
Due to its high load-bearing capacity podszybowych brackets, bolts and fasteners for the same bolts can be installed very heavy and large windows - up to 350 kg, the surface area of ​​glass from 4 to 6 m2.
"Classification of fire resistance curtain wall system Hueck-Hartmann VF 50/60 (RR) from Eduard Hueck GmbH & Co.KG". Document No. NP-881 / A / 03 / ZL issued by the Building Research Institute.

The dimensions of the profiles view: 50 mm

Zone insulator.
Profile insulator made of glass fiber reinforced polypropylene (PP).

Glazing and gaskets.
Internal seals, Edging for sealing the rear windows are made of synthetic rubber EPDM.
The seal in the form of two outer seal standard or alternatively, the overcoat multilocular, also made of EPDM. In the case of the seal jacket, in connection transom and mullion (nodes "T", "L", "cross"), special fittings retreated.

Thick fillings.
21 - 48 mm for the insulator PP
Tests.
Water resistance: Class RE750, in accordance with EN 12154
Air permeability: Class A4, in accordance with EN 12152
Thermal insulation:
UR between 1.7 W / m2K and 3.2 W / m2K (profiles insulator PP)

Burglar: WK2, WK3, according to EN 1627
Surface treatment.
Anodic oxide coatings, surface preparation according to DIN 17611
Polyester powder coating, surface preparation according to EN ISO 3892

The quality management system: according to EN ISO 9001.

Contact

Regulations | Contact