Laying Voltexu from the bottom of the housing trench (no water pressure)

Drawings

Laying Voltexu from the bottom of the housing trench (without napo

Laying Voltexu from the bottom of the housing trench (without napo

Laying Voltexu from the bottom of the housing trench (without napo


The procedures described in this section allows construction techniques for the construction of external objects
of almost equal size limits plot budowlanej.Voltex is the most effective way to isolate
przeciwwodnego buildings, the permanent shoring foundation also perform the role of formwork
structure. These are: ćcianki
Berlin, ćcianki of steel sheet piling, diaphragm and ćcianki ćcianki of bored piles, etc.
Voltex for permanent housing trench, laid the darker side of (fabric) to the installer.
In individual cases, you should refer to the relevant points of this chapter, containing
information on surface preparation and detailed installation instructions.

After laying on the housing Voltexu excavation and concreting ćciany structural object is achieved link
Voltexu with ćcianą. Using Voltex to ćcianie excavation can be performed ćciany Design
metodaminatryskowymi. Torkret should be applied in the direction of betting Voltexu so as not to
getting between established bands and pooddzielał ich.2.1 General rules laying on obudowachSąsiednie
Voltexu band is placed on the basket of at least 10 cm and secured to the housing gwoździamio wide heads in
spacing of approx. 30 cm.W conditions of lack of water pressure, the first band Voltexu installed horizontally on the
obudowywykopu bottom.
Under conditions where cićnienia hydrostatic Voltex installed vertically should connect with nazakład
Voltex exiting from the plate on a most-less 30 cm. In cases where more than 15 cićnieniehydrostatyczne
m water column, należyskonsultować the distributor for detailed installation instructions.

To carry out the insulation Voltexu penetrating the wiring installation and heads ćciągów
anchor in Voltexie should be appropriate cutouts.
After careful matching Voltexu, the point of contact must-core fill all Bentosealem completely wypełniającwolne spaces between penetrating elementema cut Voltex. For przejćcia
compact group of wires, cutting the Voltexie each is niewłaćciwe. In this case, it should
rather make cutouts outer contour of the battery cables and the space between the cover layer Bentosealu as gruboćci min. 2 cm, reaching for each pipe.